ROLPIN TA
Rolpin TA is a plywood made of MARITIME PINE (French origin) intended for outdoor use. Wooden houses, outdoor coverings, chalets, garden sheds, fences, etc.
The Plus :
– NF Extérieur CTB-X
– Class 4 or Class 3
– Treatment type class III
– Sanded faces
Where to find this product?
See the two sides above:
Product features
Side I | without knots, with wood repairs |
Face II | with sound knots, wood repair and putty |
Side III | without repair, with knotholes and slits |
Features
Standards
Read more
Features
Dimensions | 2500 x 1250 mm |
Thicknesses | 15 |
Package size | 33 |
Density | 560 to 610 kg/m3 |
Uses | The core impregnation gives the wood excellent aging properties and long-term protection against rot, mold, insects and termites. The panels are suitable for use as is, without additional protection. The preservation treatment is carried out with a product free of chromium and arsenic, which does not present any toxicological risk to health and the environment according to the information available to date. |
Bonding | According to EN 314-2: bonding class 3 “outdoor environments”, water and weather resistant. Phenolic glue. |
Options | Cutting and machining on request. |
Standards
Structural jobs in construction / TA = Non-structural jobs. | System 2+ certificate of conformity according to EN 13986 + A1 |
Outdoor environments | According to EN 636 + A1 (structural use). Approved to the French quality mark NF Extérieur CTBX and to the German mark BFU 100 DIN 68705 part 3. |
Release of formaldehyde | Classification E1 According to EN 717.2 Formaldehyde emission measurements show a release of 0.02 mg/l of air according to the ISO 12460-4 desiccant method. This value is 15 times lower than the requirements of the Japanese standard F****, the most stringent in the world (0.3 mg/l) according to JIS A 1460. |
Reaction to fire classification | According to EN 13501-1 + A1 Thickness > 9 mm : Euroclass D-s2, d0 |
CE marking | n° 380 – CPD – 011 – EN 13986 + A1 |
Read more
Storage | It is advisable to store the packages in a dry place, preferably flat and level on dry rafters insulating them from the ground. The spacing between rafters is to be adapted to the thickness and nature of the stored panels. When storing in multiple stacks, align the rafters in height. On site, provide shelter or cover the panels with a waterproof but vapor permeable coating. |
Implementation | Comply with the rules of the art, safety and the DTU in force. |
Dimensional tolerances of the panels | They comply with the specifications of the EN 315 standard:
|
Other features | Thermal conductivity Pentachlorophenol content λ = 0,13W/.K |
For more information and to consult the mechanical characteristics, download the data sheet available below.